Features:

  • Drive up to Four 350 Ω Bridges
  • Adjustable Excitation Power Supply
  • Sense Lead Compensation
  • Easy to Cancel or Tare Out Deadweights
  • One Minute Setup for Hundreds of I/O Ranges
  • Full 3-Way Input/Output/Power Isolation
  • Hot-Swappable Plug-In Design
  • Non-Interactive Zero and Span
  • Full 3-Way Input/Output/Power Isolation
  • Input and Output LoopTracker® LEDs
  • Output Test or Calibration Resistor Options

Applications:

  • Load Cell Weighing Systems and Scales
  • Strain Gauge Pressure Sensors and Transducers
  • Tanks, Scales, Extruder Melt Pressure, Crane Loads

The API 4059 G accepts a strain gauge, bridge, load cell, or a summed input from up to four sensors, and provides a proportional, isolated DC voltage or current output. It includes filtering and processing to allow effective use of low-level transducers in the noisy environments found in industrial applications. The full 3-way (input, output, power) isolation makes this module useful for ground loop elimination, common mode signal rejection or noise pickup reduction.

The 120 mA adjustable bridge excitation power supply generates a stable source of excitation voltage to drive from one to four 350 W (or greater) bridge type sensors such as load cells, pressure transducers and strain gauges and amplifies and converts the resulting millivolt signal into the selected output. Sense lead circuitry is included to cancel the effects of leadwire resistance, if required.

Input, output, excitation and zero offset are field configurable, via external rotary and slide switches. Common ranges are on the module label. Offsets up to ±100% of span can be used to cancel sensor offsets or non-zero deadweights (taring). Noninteractive zero and span simplifies calibration.

LoopTracker

API exclusive features include two LoopTracker LEDs (green for input, red for output) that vary in intensity with changes in the process input and output signals. These provide a quick visual picture of your process loop at all times and can greatly aid in saving time during initial startup and/or troubleshooting.

Output Test

An API exclusive feature includes the test button to provide a fixed output (independent of the input) when held depressed. The output test button greatly aids in saving time during initial startup and/or troubleshooting. The test output level is potentiometer adjustable from 0 to 100% of output span. A calibration resistor switch replaces the test button.

Mounting

The API 4059 G plugs into an industry standard 11-Pin octal socket sold separately. Sockets API 011 and finger-safe API 011 FS allow either DIN rail or panel mounting.

Specifications Table:

Input One to Four 350 W Sensors, 0-5 mV to 0-400 mV, 4-10 VDC Excitation
Output 0-1 V to ±10 V or 0-1 mA to 4-20 mA, Isolated
Strain Gauge Input Range
  • Minimum: 0 to 5 mV range 0.5 mV/V sensitivity
  • Maximum: 0 to 400 mV range 40 mV/V sensitivity
  • Millivolt output range is determined by the sensor sensitivity (mV/V) and the excitation voltage: mV/V sensitivity X excitation voltage = total mV range
Input Impedance 200 kΩ typical
Common Mode Rejection 100 dB minimum
Excitation Voltage
  • Maximum output: 10 VDC maximum at 120 mA
  • Drive capability: Up to four 350 Ω bridges at 10 VDC
  • Switch-selectable: 0-10 VDC in 1 V increments
  • Fine adjustment: ±5% via multi-turn potentiometer
  • Stability: ±0.01% per °C
Sense Lead Compensation Better than ±0.01% per 1 W change in leadwire resistance. 10 W max. for 10 VDC excitation w. 350 W bridge
Zero Offset (Tare) ±100% of span in 15% increments
DC Output Ranges
  • Voltage: 0-1 VDC to 0-10 VDC
  • Bipolar voltage: ±1 VDC to ±10 VDC
  • Current: 0-2 mADC to 0-25 mADC 20 V compliance, 1000 W at 20 mA
Output Calibration Non-interactive multi-turn zero and span potentiometers (±15% of span adjustment range typical)
Zero Offset ±100% of span in 15% increments
Output Test Adjustable 0-100% of span
Output Ripple and Noise Less than 10 mVRMS
Linearity Better than ±0.1% of span
Ambient Temperature Range and Stability
  • “10°C to +60°C operating ambient
  • Better than ±0.02% of span per °C stability, calculated, not tested
Response Time 70 milliseconds typical (14.2 Hz)
Isolation
  • 2000 VRMS minimum
  • Full isolation: power to input, power to output, input to output
Housing and Sockets
  • IP 40, requires installation in panel or enclosure
  • Plugs into API 011 or API 011 FS socket
  • Socket mounts to 35 mm DIN rail or can be surface mounted
Power 115 VAC ±10%, 50/60 Hz, 2.5 W max