Home » Shop » hot sale » Absolute Process Instruments API 1620 G _ AC input single alarm for inputs up to 5 Amps AC

Absolute Process Instruments API 1620 G _ AC input single alarm for inputs up to 5 Amps AC

Original price was: $311.20.Current price is: $184.25.

Sale!

44 in stock

SKU: API 1620 G Category:

Absolute Process Instruments API 1620 G _ AC input single alarm for inputs up to 5 Amps AC

Features with all optional accessories:

  • Precision Internal AC/DC Converter
  • Field Adjustable Setpoints
  • Plug-In Design for Fast Installation
  • Input LoopTracker ® and Alarm Status LEDs
  • Alarm Test Button

Applications:

  • Process Limit Backup Alarm
  • Over, Under, Out-of-Range Voltage or Current Alarm
  • Heater Break, Conveyor Jam Alarm

The API 1620 G are factory configured for an AC voltage or current input and provide alarm contact outputs. Heavy duty relay contacts allow the module to directly control high capacity loads.

The API 1620 G contains two independent setpoints with two SPDT relay contact outputs. The alarm outputs are normal acting can be factory or user configured for HI/HI, HI/LO, LO/HI or LO/LO operation. Top-accessible potentiometers are used to adjust each alarm setpoint. Deadband is fixed at 1% of span. Adjustable deadbands are optional.

LoopTracker and Alarm Status LEDs

API exclusive features include a LoopTracker LED that varies in intensity with changes in the input signal. A two red/green bi-color alarm status LED visually indicate alarm status. These LEDs provide a quick visual picture of your process at all times.

Output Test

API’s exclusive functional test button can be used to verify the alarm and system operation. Press the Test button to toggle the alarm relay(s) to the opposite state. The output test button greatly aids in saving time during initial startup and/or troubleshooting.

Specifications Table:

Input 0-50 mVAC to 0-300 VAC, 0-1 mAAC to 0-900 mAAC
Output One 8 Amp DPDT Relay or Two 8 Amp SPDT Relays
AC Input Range Factory configured, please specify AC input range

  • Voltage: 0-50 mVAC to 0-300 VAC
  • Current: 0-1 mAAC to 0-900 mAAC
  • System voltages must not exceed socket voltage rating
Input Impedance (Voltage Input) 220 kΩ minimum
Input Voltage Burden (Current Input) 1.0 VRMS maximum
Input Frequency 40 Hz to 1000 Hz sinusoidal
Input Protection, Common Mode 750 VDC or 750 VACp
Relay Output
  • Two independent SPDT form C contact sets
  • Two setpoints, two 12 turn potentiometers, 0-100% of span
  • Normal acting alarms
  • Standard: HI/LO alarm
  • Options: LO/LO, HI/HI, LO/HI alarms
  • Internal jumpers for HI/LO, LO/LO, HI/HI, LO/HI
Deadband Alarm trip/reset window is symmetrical about the setpoint (Fixed at 1% of span, standard)
Output Test Button Toggles relay(s) to opposite state when pressed
Response Time 70 milliseconds typical
Ambient Temperature Range and Stability
  • “10°C to +60°C operating ambient
  • Better than ±0.02% of span per °C stability, calculated, not tested
Housing
  • IP 40, requires installation in panel or enclosure
  • API 011 or API 011 FS socket
Sockets Socket mounts to 35 mm DIN rail or can be surface mounted
Power 115 VAC ±10%, 50/60 Hz, 2.5 W max